  Datasheet File OCR Text:
  the mbc120 series of open frame medical power supplies feature a wide universal ac input range of 85 v C 264 vac, offering 120 w of output power in a compact footprint, with a variety of isolated single output voltages. the mbc series is designed and approved to the latest medical standards (en/iec 60601 - 1), providing 2 x mopp isolation for class i & class ii applications. these power supplies a re ideal for medical, telecom, d atacom, in dustrial equipment and other applications. ? 3 x 2 inch footprint ? 120 watts with forced air cooling ? approved to en/iec 60601 - 1 ? efficiencies up to 93% ? - 40 to 70c operating temperature ? dual fusing ? thermal shut - down feature ? >3.00 million hours, telcordia - sr332 - issue 3 ? standby power < 0.3 w ? class ii option available ? rohs compliant ? ce marked ? diagnostic ? drug pump ? dialysis ? home health care ? monitoring ? portable equipment
2 mbc120 series tech.support@psbel.com mbc120 - 1t12l mbc120 - 1012l screw terminal molex header 12 v 8.33 a 10.0 a 0.0 a 1% mbc120 - 1t15l mbc120 - 1015l screw terminal molex header 15 v 6.66 a 8.0 a 0.0 a 1% mbc120 - 1t24l mbc120 - 1024l screw terminal molex header 24 v 4.16 a 5.0 a 0.0 a 1% mbc120 - 1t30l mbc120 - 1030l screw terminal molex header 30 v 3.33 a 4.0 a 0.0 a 1% mbc120 - 1t48l mbc120 - 1048l screw terminal molex header 48 v 2.08 a 2.5 a 0.0 a 1% mbc120 - 1t58l mbc120 - 1058l screw terminal molex header 58 v 1.72 a 2.07 a 0.0 a 1% cover - 120 - xbc 3 metal cover kit accessory specifications are for nominal input voltage, 25c unless otherwise stated. input voltage universal (see derating under output power) 85 - 264 vac / 390 vdc 4 input frequency 47 - 63 hz input current 115 vac: 230 vac: 1.2 a max. 0.65 a max. no load power typical < 0.3 w inrush current 115 vac: 230 vac: 264 vac: 25 a 45 a 75 a leakage current typical (n.a. for class ii option) touch current 300 ua <100 ua power factor @ full load, active pfc > 0.95 switching frequency typical 60 khz 1 for class ii option (without input earth pin) add suffix: - 2 (e.g.: mbc120 - 1012l - 2). 2 ripple is peak to peak with 20 mhz bandwidth and 10 f (tantalum capacitor) in parallel with a 0.1 f capacitor at rated line voltage and load ranges. 3 when used in cover kit, de - rate output power to 70 % under all operating conditions 4 functional, not approved.
mbc120 series 3 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 201 7 bel power solutions & protection bcd.00 667 _a c output power forced cooling (with 200 lfm): convection cooling (for input 100 - 264 vac, de - rate linearly to 80 w @ 85 vac): 120 w 100 w efficiency 48 v, 58 v: 24 v, 30 v: 12 v, 15 v: 93% 91% 90% hold - up time typical >10 ms line regulation +/ - 0.5% load regulation +/ - 1% transient response 25% step load change, at 0.1a/us slew rate, 50% duty cycle, 50 hz = 4% recovery time < 5 ms voltage adjustment +/ - 3% rise time typical 55 ms set point tolerance +/ - 1% over current protection > 110% over voltage protection latch type (ac recycling required) 110 to 140% short circuit protection hiccup mode operating temperature 5 startup guaranteed ( derate linearly above 50c to 70c as per f ig 1) - 40 to +70c - 40 to 0c storage temperature - 40 to +85c cooling forced: with 300 lfm (refer to mech. drawing) convection: for input 100 - 264 vac (derate linearly to 80 w @ 85 vac) 120 w 100 w relative humidity noncondensing 5% to 95% altitude operating: nonoperating: 16,000 ft 40,000 ft. reliability mtbf according to telcordia C sr332 - issue 3 3.00 million hours conducted emissions en 55011 - b, cispr22 - b, fcc part15 - b pass radiated emissions en 55011 a; with external core (king core k5b rc 25x12x15 - m in input cable) pass level b input current harmonics en 61000 - 3 - 2 class d voltage fluctuation and flicker en 61000 - 3 - 3 pass esd immunity en 61000 - 4 - 2 level 4, criterion a radiated field immunity en 61000 - 4 - 3 level 3, criterion a electrical fast transient immunity en 61000 - 4 - 4 level 3, criterion a surge immunity en 61000 - 4 - 5 level 3, criterion a conducted immunity en 61000 - 4 - 6 level 3, criterion a magnetic field immunity en 61000 - 4 - 8 level 4, criterion a voltage dips, interruptions en 61000 - 4 - 11 criterion b 5 output ripple can be more than 10% of the output voltage.
4 mbc120 series tech.support@psbel.com isolation voltage input to output: (for medical applications ) input to gnd: (not applicable for class ii option) output to gnd : for type bf for type b (n/a for class ii option) 4 000 vac 1500 vac 1500 vac 500 vac protection level primary to secondary: primary to earth: secondary to earth: 2 mopp 1 mopp 1 mopp safety standard(s) approved to the latest edition of the following standards: csa/ul60601 - 1, en60601 - 1 and iec60601 - 1. agency approvals nemko, culus, cb ce mark complies with lvd directive convection load: 100 w up to 50 c de - rate above 50 c @ 2.5% per c forced air cooled load : 120 w up to 50c de - rate above 50 c @ 2.5% per c figure 1. derating curve ac input connector j1 pin 1 pin 2 pin 3 ac line not fitted ac neutral screw terminal (option 1) molex: 39357 - 0003 tyco - 2 - 1776112 - 3 molex header (option 2) molex: 1722861103 (mating conn: molex 1722561003) dc output connector j2 pin 1, 2 pin 3, 4 v1 - ve v1 +ve screw terminal (option 1) molex: 39357 - 0004 tyco - 2 - 1776112 - 4 molex header (option 2) molex: 1722861104 (mating conn: molex 1722561004) weight 150 g dimensions 76.2 x 50.8 x 30.1 mm (3 x 2 x 1 .18 inch)
mbc120 series 5 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 201 7 bel power solutions & protection bcd.00 667 _a c figure 2. mechanical drawing - screw terminal (option 1) figure 3. mechanical drawing - molex header (option 2) notes: in case the pcb is mounted in a metal enclosure, using metal hardware ensure the following: 1 stand off, used to mount pcb has od of 5.4 mm max. 2 screws, used to fix pcb on stand off, have head dia of 6.0 mm max. 3 washer, if used, to have dia of 6.5 mm max. nuclear and medical applications - products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. specifications are subject to change wi thout notice.


▲Up To Search▲   

 
Price & Availability of COVER-120-XBC3

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X